Gaugewise

12 V, 24 V and 48 V Wire Size Calculator

The smallest 12, 24 or 48 V DC conductor for your drop target, with the round trip included, in mm² and AWG.

Calculator

Presets only; check your local supply.
Load
Inverters, LED drivers and chargers draw more current as voltage falls.
The return conductor is included automatically.
Resistance is corrected from 20 °C.
Your choice, not a standard.

Enter the voltage you want to size for, for example the lowest battery voltage you expect.

What is different at low voltage

Worked examples, 20 °C

10 A through 5 m of 4 mm²DropPercent
12 V0.431 V3.59%
24 V0.431 V1.80%
48 V0.431 V0.90%

Constant power: 120 W at 12 V, 5 m one way, 4 mm² copper. Voltage at the load 11.552 V, drop 0.448 V (3.73%), current 10.39 A. A fixed 10 A through the same cable gives 3.59%.

The 3%, 5% and 10% buttons are choices, labelled Tighter, Typical and Relaxed. They are not standards, and this page makes no claim about marine, RV or vehicle rules. Fuse and breaker sizing and cable ratings are not covered.

Questions

Do I enter the round-trip length?

No. Enter the one-way run from the source to the load. The return conductor is included.

Which voltage should I enter?

The voltage at the source that you want to plan for. Many people use the lowest battery voltage they expect, because the percentage drop is largest there. The calculator does not choose it for you.

Can this size a fuse or breaker?

No. It estimates voltage drop only. Cable ratings and protection come from your datasheets and the rules where you work.

Sources and constants

Constants and formulas: method, constants and changelog (engine 1.0.0-web, constants checked 2026-11-18). Found a mistake? Report a calculation error.

Related

Get the app

Want the same numbers on your phone, offline and with your assumptions saved? Gaugewise is a free Android calculator with no ads and no account.

Coming soon to Google Play

Last reviewed 2026-11-18. Engine 1.0.0-web.

Design aid. Estimates from physics and the values you entered; not a code check. Final wire selection remains the installer's responsibility. Full disclaimer.