12 V, 24 V and 48 V Wire Size Calculator
The smallest 12, 24 or 48 V DC conductor for your drop target, with the round trip included, in mm² and AWG.
What is different at low voltage
- Round trip. The current goes out on one conductor and back on the other, so the loop is twice the one-way run.
- Percent grows fast. The same cable and current drop the same volts at any supply voltage, so the percentage is four times larger at 12 V than at 48 V.
- Constant-power loads. A device that draws constant power takes more current as the voltage sags, which makes the drop slightly worse than a fixed-current estimate.
Worked examples, 20 °C
| 10 A through 5 m of 4 mm² | Drop | Percent |
|---|---|---|
| 12 V | 0.431 V | 3.59% |
| 24 V | 0.431 V | 1.80% |
| 48 V | 0.431 V | 0.90% |
Constant power: 120 W at 12 V, 5 m one way, 4 mm² copper. Voltage at the load 11.552 V, drop 0.448 V (3.73%), current 10.39 A. A fixed 10 A through the same cable gives 3.59%.
The 3%, 5% and 10% buttons are choices, labelled Tighter, Typical and Relaxed. They are not standards, and this page makes no claim about marine, RV or vehicle rules. Fuse and breaker sizing and cable ratings are not covered.
Questions
Do I enter the round-trip length?
No. Enter the one-way run from the source to the load. The return conductor is included.
Which voltage should I enter?
The voltage at the source that you want to plan for. Many people use the lowest battery voltage they expect, because the percentage drop is largest there. The calculator does not choose it for you.
Can this size a fuse or breaker?
No. It estimates voltage drop only. Cable ratings and protection come from your datasheets and the rules where you work.
Sources and constants
- Copper Wire Tables, NBS Handbook / Circular No. 31 (1914), NIST archive
- ASTM B258, standard nominal diameters and cross-sectional areas of AWG sizes (the standard itself is paywalled and is not reproduced here)
Related
Get the app
Want the same numbers on your phone, offline and with your assumptions saved? Gaugewise is a free Android calculator with no ads and no account.
Design aid. Estimates from physics and the values you entered; not a code check. Final wire selection remains the installer's responsibility. Full disclaimer.