Gaugewise

Frequently asked questions

Is Gaugewise free?

Gaugewise is free to use. Voltage drop, size selection, checking an existing cable, mm² and AWG, 12 to 48 V mode, split-phase and parallel runs, extension cord mode, your own ratings, backup and one job sheet are free. Pro is a one-time purchase that adds PDF reports, unlimited job sheets and history, upsize payback and motor start.

Do I need an account?

No. Gaugewise has no account and no sign-in.

Does it work offline?

Yes. All calculations run on your phone and the app does not need a network connection.

Why do I enter the ampacity myself?

Gaugewise does not ship code tables. You enter the current rating from your cable datasheet or your own reference, or import your own table, and the app uses that value for its checks and lists it in the assumptions. The table stays on your phone.

Does it follow a national electrical code?

The app makes no claim of conformity with any code, standard or regulation. It calculates from physics and the values you enter, and it is a design aid. Local rules may be stricter, so check them. Final wire selection remains the installer’s responsibility.

Does it give a verdict on my cable?

No. It reports whether the voltage drop is within or above the target you set, shows what decided the size, and says how the load compares with the rating you entered. Targets are your choice, not a standard.

Do I enter the one-way length or the total?

You enter the one-way run length and the return conductor is included automatically for DC and single-phase circuits. You can switch to total conductor length, and the assumptions card always shows which one is used.

Which constants does it use?

Resistivity of copper and aluminum at 20 °C with a linear temperature correction, as listed on the method and constants page. The values appear in the assumptions of every result, and you can enter a datasheet resistance instead.

Does it handle both mm² and AWG?

Yes. Both series are first-class: the app shows the nearest size in each, converts AWG, kcmil and mm² using the AWG definition, and tells you when the two nearest sizes are different nominal areas.

Does it cover 12 V boat or RV wiring?

Yes. The low-voltage DC mode (12, 24 and 48 V) assumes a round trip, offers 3%, 5% and 10% targets and supports constant-power loads. It makes no claim about marine or vehicle standards.

Does it support split-phase and parallel runs?

Yes. Split-phase 120/240 V loads (line-to-line, line-to-neutral and unbalanced) and several identical conductors in parallel are both free.

Can it replace an electrician or a design?

No. It is a design aid. The installer remains responsible for the final selection and for following local rules.

Do the website calculators send my numbers anywhere?

No. The calculators on this website run in your browser and the values you type are not sent to a server.

How do I restore my purchase?

Open More, then Restore purchases, with the same Google account you used to buy Pro.

How do I delete my data?

There is no account. See Delete your data for the steps.

How do I cancel?

There is no subscription. Pro is a one-time purchase.

Something missing? Ask us.